Jobs Career Advice Post Job
X

Send this job to a friend

X

Did you notice an error or suspect this job is scam? Tell us.

  • Posted: Oct 3, 2025
    Deadline: Not specified
    • @gmail.com
    • @yahoo.com
    • @outlook.com
  • Never pay for any CBT, test or assessment as part of any recruitment process. When in doubt, contact us

    Equity Bank Limited (The "Bank”) is incorporated, registered under the Kenyan Companies Act Cap 486 and domiciled in Kenya. The address of the Bank’s registered office is 9th Floor, Equity Centre, P.O. Box 75104 - 00200 Nairobi. The Bank is licensed under the Kenya Banking Act (Chapter 488), and continues to offer retail banking, microfinance and relat...
    Read more about this company

     

    Data Centre Manager - Power and Cooling

    • The Datacenter Power and Mechanical Systems Manager is responsible for the operation, maintenance, capacity planning, and reliability of all critical power and mechanical infrastructure within the datacenter. This includes utility power feeds, generators, UPS systems, switchgear, PDUs, chillers, CRAC/CRAH units, containment systems, and environmental controls. The role ensures the resilience and optimal performance of all mechanical and electrical systems, supporting continuous availability and compliance with regulatory and operational standards.

    Key Responsibilities / Accountabilities 

    • Power Infrastructure Management
    • Oversee the operation and maintenance of all electrical infrastructure including utility feeds, switchgear, generators, ATS/STS systems, UPS systems, and power distribution networks (MDBs, SDBs, PDUs, rPDUs).
    • Monitor power systems for capacity, load balance, and redundancy, ensuring adherence to Tier III/IV design principles.
    • Coordinate planned maintenance and testing (e.g., generator load tests, UPS battery autonomy tests) to minimize operational risk.
    • Manage fault response and escalation for power-related incidents, ensuring timely restoration and root cause analysis. 
    • Mechanical & Cooling Systems Management
    • Manage HVAC and mechanical systems including CRAC/CRAH units, condensers, in-row coolers, and containment systems.
    • Optimize cooling performance through airflow management, temperature/humidity control, and system tuning to improve energy efficiency.
    • Supervise maintenance and emergency repairs on mechanical systems, ensuring compliance with OEM standards and preventive maintenance schedules.
    • Preventive Maintenance & Reliability
    • Own the preventive and corrective maintenance calendar for all power and mechanical systems.
    • Supervise vendor activities and ensure adherence to safety, quality, and operational procedures.
    • Conduct system redundancy and failover testing to verify resilience under various operating scenarios.
    • Maintain detailed maintenance records, test reports, and system performance data for audits and reviews.
    • Capacity Planning & Projects
    • Analyze and forecast power and cooling capacity utilization, identifying headroom and upgrade requirements.
    • Provide technical input for datacenter expansion, technology refresh, or sustainability projects (e.g., containment retrofits, solar integration, UPS upgrades).
    • Work closely with internal teams and external contractors to plan and execute infrastructure projects with minimal operational impact. 
    • Compliance, Documentation & Reporting
    • Maintain accurate single-line diagrams, mechanical schematics, asset inventories, and operation manuals.
    • Ensure all systems and procedures comply with regulatory standards, internal policies, and Uptime Institute/ISO requirements.
    • Produce regular reports on system performance, incidents, capacity utilization, energy efficiency (PUE), and maintenance KPIs.
    • Support audits and inspections by providing accurate and complete technical documentation.

     Qualifications & Experience

    • Degree in Electrical or Mechanical Engineering, or related technical field.
    • 3-5 years work experience
    • Hands-on experience with power distribution systems, UPS/generator operations, HVAC systems, and maintenance planning.
    • Relevant certifications such as CDCP/CDCS, Uptime ATS/ATD, or OEM vendor certifications are an advantage.
    • Proven track record in reliability engineering, preventive maintenance, and capacity planning.
    • In-depth knowledge of low-voltage power distribution, UPS systems, generators, switchgear, and power quality management.
    • Strong understanding of HVAC systems, chillers, CRAC/CRAH units, airflow management, and mechanical plant operations.
    • Familiarity with BMS/DCIM platforms for monitoring and alarm management.
    • Awareness of Tier III/IV datacenter design standards, energy efficiency principles, and relevant regulatory codes.
    • Strong technical leadership in electrical and mechanical systems
    • Excellent planning, coordination, and vendor management skills
    • Analytical mindset for capacity forecasting and incident analysis
    • High attention to detail in documentation and compliance
    •  Effective communication and escalation discipline
    • Professionalism under pressure in critical environment.

    Check how your CV aligns with this job

    Method of Application

    Interested and qualified? Go to Equity Bank Kenya on equitybank.taleo.net to apply

    Build your CV for free. Download in different templates.

  • Send your application

    View All Vacancies at Equity Bank Kenya Back To Home

Subscribe to Job Alert

 

Join our happy subscribers

 
 
Send your application through

GmailGmail YahoomailYahoomail